日韩国产在线高清一区_色图二区视频在线观看免费视频日韩_欧美日韩国产人成在线观看_720lu在线刺激视频国产_亚洲综合欧美激情_可观看的黄色视频网站_日韩中文字幕二区_波多野结系列无码观看潮_国产av巨制丝袜秘书_老男人久久青草av高清

Precision air conditionin
Guangzhou Granden Electronic Technology Co.,Ltd
Address: Guangzhou city Tianhe District Longkou Road West 77 803room
Phone: 020-87540643
Fax: 020-87540663
Technical support: 13824476182
Website:www.gedz.com.cn
The Current Position >> Home >> Product >>
Spark gap complex DEHNventil M TNC 255 (DV M TNC 255), DEHNvent

Product introduction

Germany DEHNventil M TT 255 (DV M TT 255), DEHNventil M TT 255 FM (DV M TT 255 FM) used for low voltage electrical equipment TT system module type composite lightning surge/surge protector, used in lightning protection partition OA - 2. Replace old type products DEHNventil TT 255 (900 375).

Function characteristics

? ? preliminary connection, the spark gap type composite lightning current/surge protector, the base and plug-in protection module

? ? RADAX Flow technology, has fly-wheel inhibition function, meet the system high reliability requirements

? ? short circuit current to 50 karms, 20 a gL/gG fuse don jump

? ? discharge capacity of 100 ka (10/350 μ s)

? ? can protect terminal equipment

? ? Windows indicating working state/fault condition

? ? with module lock device, through the module release button easily replace protection module

? ? through the impact and vibration test, on the basis of the EN60068-2

Technical parameters

DV M TT 255 DV M TT 255 FM

According to the EN 61643-11, SPD grade 1 grade 1

According to IEC 61643-1, SPD Ⅰ level Ⅰ level

Ac nominal voltage UN 230/400 v 230/400 v

Ac maximum continuous working voltage UC 255 v, 255 v

Lightning surge current (10/350 μ s) [L1 + L2 + L3 - N - PE] Itotal 100 ka 100 ka

Lightning surge current (10/350 μ s) [L - N] Iimp 25 ka 25 ka

Lightning surge current (10/350 μ s) [N - PE] Iimp 100 ka 100 ka

Nominal discharge current (8/20 μ s) In 25/100 ka 25/100 ka

Voltage protection level [L - PE] Up acuities were 1.5 kV acuities were 1.5 kV

Voltage protection level [N - PE] Up acuities were 1.5 kV acuities were 1.5 kV

Power frequency fly-wheel interrupting capacity [L - N] Ifi 50 karms 50 karms

Power frequency fly-wheel interrupting capacity [N - PE] Ifi and and

Fly-wheel inhibition/selective expected fly-wheel to 50 karms, 20 a fuse don jump expected fly-wheel to 50 karms, 20 a fuse don jump

Response time tA acuities 100 ns acuities 100 ns

Ik = 50 karms, maximum backup fuse (L) 315 a gL/gG 315 a gL/gG

Ik > 50 karms, maximum backup fuse (L) 200 a gL/gG 200 a gL/gG

Maximum backup fuse (L - L ) 125 a gL/gG 125 a gL/gG

Transient overvoltage (TOV) [L - N] UT 440 v / 5 SEC. 440 v / 5 SEC.

Transient overvoltage (TOV) [N - PE] UT 1200 v / 200 ms 1200 v / 200 ms

Working temperature range (parallel) TUP - 40 ℃... + 80 ℃ to 40 ℃... + 80 ℃

Working temperature range (series) TUS - 40 ℃... + 60 ℃ to 40 ℃... + 60 ℃

Working state/fault indicator green/red green/red

The minimum installation conductor sectional area (L1, L1, L2, L3, L2, L3 , N, N , PE, 〨) 10 best callus induction stranded wire/soft line 10 best callus induction stranded wire/soft line

Maximum installation conductor sectional area (L1, L2, L3, N, PE) 50 best callus induction stranded wire/best callus induction and soft line 50 best callus induction stranded wire/best callus induction and soft line

Maximum installation conductor sectional area (L1, L2, L3 , N , 〨) 50 best callus induction stranded wire / 25 best callus induction soft line 50 best callus induction stranded wire / 25 best callus induction soft line

Installation and mmdin rail, on the basis of the EN 60715 35 mmdin rail, on the basis of the EN 60715

Shell material red thermoplastic materials, UL 94-0 red thermoplastic materials, UL 94-0

Protection level IP 20 IP 20

Size 6 mods, DIN 43880 6 mods, DIN 43880

The authentication KEMA, VDE, UL, VdS KEMA, VDE, UL, VdS

Remote signalling contact type - float switch contact

Ac switching capacity - 250 v / 0.5 A

Dc switching capacity - 250 v / 0.1 A; 125 v / 0.2 A; 75 v / 0.5 A

Remote signalling terminal of the cross sectional area - maximum 1.5 the best callus induction stranded wire