The Current Position >> Home >> Product >>
Level 1 power lightning protection device DEHNguard T 100 385 (DG T 100 385), DEHNguard

Product introduction

Germany DEHNguard T 100 385 (DG T 100 385), DEHNguard T 100 FM (DG T 100 FM) level power surge protector to protect low voltage electrical equipment, to prevent the surge, used to protect lightning protection partition OB - 1 and subsequent partition.

Function characteristics

? ? by powerful zinc oxide varistor of 100 ka (8/20 μ s) high discharge capacity.

? ? fast response.

? ? by base and plug-in protection module two element composition.

? ? with a "dynamic thermal trip" monitoring devices, which has the high reliability.

? ? and red line series product energy coordination.

? ? fault indicator with a red marker appeared in monitoring window.

? ? according to DIN 43880, the design of small size (module).

? ? multi-function terminal, used for connecting wire and bus.

? ? can be equipped with remote signalling contact, used for SPD monitoring device.

Technical parameters

DG T 100 DG T 100 FM

According to the EN 61643-11, SPD level 2 level 2

According to IEC 61643-1, SPD level II level II

Ac nominal voltage UN 230 v, 230 v

Ac maximum continuous working voltage UC 385 v, 385 v

Dc maximum continuous working voltage UC 500 v, 500 v

Nominal discharge current (8/20 μ s) In 40 ka 40 ka

Maximum discharge current (8/20 μ s) Imax 100 ka 100 ka

Voltage protection level Up acuities were 1.75 kV acuities were 1.75 kV

5 ka, voltage protection level Up acuities were 1.35 kV acuities were 1.35 kV

Response time tA acuities 25 ns acuities 25 ns

Maximum backup fuse 250 agl/Gg 250 agl/Gg

Maximum backup fuse when short circuit tolerance ability 20 karms 20 karms

Operating temperature range TU - 40 ℃... + 80 ℃ to 40 ℃... + 80 ℃

Installation conductor sectional area (minimum) 1.5 the best callus induction stranded wire/soft line 1.5 the best callus induction stranded wire/soft line

Installation conductor sectional area (maximum) and the best callus induction stranded wire / 25 best callus induction soft line and the best callus induction stranded wire / 25 best callus induction soft line

Installation and mmdin rail, on the basis of the EN 60715 35 mmdin rail, on the basis of the EN 60715

Shell material red thermoplastic materials, UL 94 v - 0 red thermoplastic materials, UL 94 v - 0

Protection level IP 20 IP 20

Size 1 mods, DIN 43880 1 mods, DIN 43880

Trip indicator green/red green/red

Remote signalling contact type - float switch contact

Ac switching capacity - 250 v / 0.5 A

Dc switching capacity - 250 v / 0.1 A; 125 v / 0.2 A; 75 v / 0.5 A

Remote signalling terminal of the cross sectional area - maximum 1.5 the best callus induction stranded wire/soft line