The secondary power supply prevents thunder device DEHNguard M TT 385 (DG M TT 385), DEHNguard M

Product introduction

Germany DEHNguard M TT 385 (DG M TT 385), DEHNguard M TT 385 FM (DG M TT 385 FM) used for low voltage electrical equipment surge protection, used in lightning protection partition OB - 1 follow-up prevent mine field.

Function characteristics

? complete preliminary terminal units, by the base and plug-in protection module

? and Red/Line series product energy coordination

? powerful zinc oxide varistor, high discharge capacity

? "dynamic heat tripping" SPD monitoring device, high safety

? multi-function terminal, can connect wires and bus

? use module release button, change protection module is simple

Technical parameters

DG M TT 385

DG M TT 385 FM

According to the EN 61643-11, SPD

Level 2

Level 2

According to IEC 61643-1, SPD

Ⅱ level

Ⅱ level

Ac nominal voltage UN

230/400 v

230/400 v

Ac maximum continuous working voltage [L - N] UC

385 v

385 v

Ac maximum continuous working voltage [N - P] UC

255 v

255 v

Nominal discharge current (8/20 μ s) In

20 ka

20 ka

Maximum discharge current (8/20 μ s) Imax

40 ka

40 ka

Lightning surge current (10/350 μ s) [N - PE] Iimp

12 ka

12 ka

Voltage protection level [N - PE] Up

Acuities were 1.75 kV

Acuities were 1.75 kV

5 ka, voltage protection level [L - N] Up

Acuities were 1.35 kV

Acuities were 1.35 kV

Voltage protection level [L - N] Up

Acuities were 1.5 kV

Acuities were 1.5 kV

Power frequency fly-wheel interrupting capacity [N - PE] Ifi

and

and

Response time [L - N] tA

Acuities 25 ns

Acuities 25 ns

Response time [N - PE] tA

Acuities 100 ns

Acuities 100 ns

Maximum backup fuse

125 a gL/gG

125 a gL/gG

Maximum backup solution wire when short circuit tolerance ability

25 karms

25 karms

Transient overvoltage (TOV) [L - N] UT

-

-

Transient overvoltage (TOV) [N - PE] UT

1200 v / 200 ms

1200 v / 200 ms

Operating temperature range TU

- 40 ℃... + 80 ℃

- 40 ℃... + 80 ℃

Working state/fault indicator

Green/red

Green/red

Installation conductor section tax (minimum)

1.5 the best callus induction stranded wire/soft line

1.5 the best callus induction stranded wire/soft line

Installation conductor section tax (maximum)

35 the best callus induction stranded wire / 25 best callus induction soft line

35 the best callus induction stranded wire / 25 best callus induction soft line

installation

35 mmdin rail, on the basis of the EN 60715

35 mmdin rail, on the basis of the EN 60715

Shell material

Red thermoplastic materials, UL 94-0

Red thermoplastic materials, UL 94-0

Protection level

IP 20

IP 20

size

4 mods, DIN 43880

4 mods, DIN 43880

The authentication

KEMA, VDE, UL, Vds

KEMA, VDE, UL, Vds

Remote signalling contact type

-

Float switch contact

Ac switching ability

-

250 v / 0.5 A

Dc switching ability

-

250 v / 0.1 A; 125 v / 0.2 A; 75 v / 0.5 A

Remote signalling terminal of the cross sectional area

-

Maximum 1.5 the best callus induction stranded wire/soft line